What the 2027 rules cover
The device, how it's run and how it's scored, in brief. Topics marked State & national are left out at regionals.
- Build a wooden cantilevered beam or truss out from a vertical wall to hold a load at a set height and distance; scored on structural efficiency plus a bonus. Teams of up to 2, about 10 minutes, eye protection B, no impound.
Event parameters
- One structure per team.
- Eye protection B (Z87+ marked) must be worn.
- Design knowledge: answer questions about how the structure was built and how it works
- At in-person tournaments the supervisor supplies the test apparatus; teams may not measure or adjust it or bring tools or instruments.
Construction parameters
- One single structure with no separate, loose or detachable parts
- Only wood bonded with adhesive; no other materials
- Attaches to the wall only by resting on the Mounting Bolt Assembly
- Supports only the Loading Block, which carries the rest of the Loading Assembly
- Chain centerline 40–45 cm out from the wall and within 2.5 cm either side of the wall's centerline
- May touch only the wall's face outside the vertical Contact Width Lines; never its sides, top or bottom
- Before sand is loaded, the Loading Block's bottom sits above the horizontal plane through the bolt's centerline
- Base option: wall contact only above the 15 cm contact depth line, otherwise Tier 2
- Bonus option: wall contact only above the 10 cm line and the structure holds 15 kg
Competition
- Before competition the supervisor checks the apparatus and that the Loading Assembly plus sand is 15,100–15,200 g.
- Check-in: no outside help or changes to the structure, inspection, estimated load submitted, structure massed to 0.01 g
- Testing
- 6 minutes to set up and test; Loading Assembly reassembled in order; bucket hung with floor clearance
- Before loading, the supervisor checks the construction requirements and the bonus requirements and bucket clearance.
- No adjusting the structure once sand loading begins.
- Teams load the sand; the bucket may be steadied only with the tips of the stabilizing sticks, never lifted or pushed
- Loading stops at failure, when anything else carries the load, on other vertical support, or when time runs out
- Load Supported: Loading Assembly plus sand, to the nearest gram, with any fallen structure pieces removed
- Minimum load is the Loading Assembly; a structure that can't hold it scores participation only
- Maximum Load Supported is 15,000 g
- The supervisor reviews the recorded data with the team; acknowledging it ends testing.
- Teams appealing must leave their structure with the supervisor.
Scoring
- High score wins: score = Load Scored / structure mass
- Load Scored Bonus of 7,500 g for meeting the bonus construction option
- Load Scored = Load Supported + Load Scored Bonus
- Tier 1 meets every requirement, Tier 2 misses one or more, and some failures score participation only
- Tiebreakers: lowest structure mass, then the estimated load closest to the actual load
Test apparatus
- The supervisor provides the apparatus in person (more than one may be used); at satellite tournaments the coach or a designee does.
- The Testing Wall
- A rigid, smooth, low-friction wall at least 40.0 cm wide by 30.0 cm high, set plumb
- One mounting bolt hole about 5.0 cm below the top, centered side to side, with its centerlines marked
- Horizontal contact depth lines 10, 15 and 20 cm below the bolt hole's center
- Vertical contact width lines 4.0 cm left and right of the bolt hole's center
- Mounting Bolt Assembly: 1/4-20 connector bolt with nuts and washers, 3.0 cm clear of the wall face; teams may not adjust it
- Loading Assembly: 5 cm square Loading Block on an eyebolt with wing nut, chain, S-hook and bucket, at most 1,500 g
- The load is applied with sand.
- Two bucket stabilizing sticks: dowels with a spring doorstop on one end.
- Structure scale: digital recommended, 0.01 g resolution recommended, 0.1 g minimum.
- Sand scale: digital recommended, about 1 g resolution recommended, 10 g minimum.
- A countdown timer that can be set to 6 minutes is recommended.
Definitions
- What counts as wood (no bark, composites, bamboo, paper or plywood) and how it may not be treated (painted, soaked, coated, modified)
- No limits on the cross-section size of wood pieces
- Teams may laminate wood themselves; commercially laminated wood is not allowed
- Any commercial adhesive, used only to join parts; no adhesive tape
- Where to buy the connector bolt and its finishes.
- Sand means a clean, dry, free-flowing material like play sand or steel shot.
Paraphrased by SciPrep from the 2027 Science Olympiad Division C Rules Manual, pages C7–C12. The official rules are in the Rules Manual from Science Olympiad; when they differ, the manual and its clarifications win.