What the 2027 rules cover
The topics and tasks the event can include, in brief. Topics marked State & national are left out at regionals.
Event parameters
- Impound one pre-built device plus tools and spare parts; all the water it needs must already be sealed inside, with no extra water impounded or supplied
- Any amount of paper notes and resources is allowed, in binders or loose; two Class III calculators may be used.
Construction parameters
- No energy storage devices (batteries, springs, rubber bands); a device with one scores zero for the battery and time scores
- The device runs entirely on hand-powered syringes
- Each joint is a Control/Actuator pair joined by tubing: competitors push or pull the Control Syringe; the Actuator (usually a syringe, possibly a balloon or similar) moves the joint
- Any number of joints and any syringe or actuator volume is allowed.
- Syringes hold only water and/or air; the water may be coloured
- Tubing between Control and Actuator must be flexible, and Control Syringes connect to the device only through that tubing
- Self-supporting on a flat surface; ready to run, the parts touching the surface (not counting Control Syringes and tubing) fit in a 25.0 cm × 25.0 cm box, any height, overhangs allowed
- The device must not damage, mark or leave residue on the Test Surface
- The supervisor may ask the team to take the device apart afterwards to check its materials.
- Be able to answer questions about the device's design, construction and operation (Building Policy)
Competition area
- A flat, smooth Test Surface at least 55 × 55 cm, marked with 1-inch masking tape
- Device Box: a taped 25.0 × 25.0 cm square with the midpoint of its front side marked
- Travel Area: a wedge centred on the Device Box's front midpoint, 45° at Regionals and States, 60° at Nationals
- Start Line: the left boundary of the Travel Area, a tape strip at least 30.0 cm long
- Finish Line: the right boundary of the Travel Area, a tape strip at least 30.0 cm long
- Goal Box: a 10.0 × 10.0 cm square to the right of the Finish Line, its side running 10.0 to 20.0 cm from the front midpoint
- Finish Zone: everything to the right of the Finish Line, Goal Box included, Device Box excluded
- Four upright 9-volt batteries on the Start Line: three Movable, one taped Unmovable
- The nearest battery is at least 3.0 cm from the Device Box, measured along the Start Line
- The farthest battery is no more than 30.0 cm from the Device Box, measured along the Start Line
- At least 3.0 cm of open space along the Start Line between batteries
- A flat, smooth Test Surface at least 55 × 55 cm, marked with 1-inch masking tape
The competition
- Part I: written test
- The written test assesses density and fluid mechanics.
- Answers in metric units with appropriate significant figures, unless asked otherwise
- Questions from each of these areas
- Density of solids, liquids and gases; relative density, number density and area density
- Pressure in liquids and gases, hydrostatic pressure, how pressure changes with depth, Pascal's principle
- Gas laws: ideal gas, Boyle's, Charles', Gay-Lussac's and Avogadro's
- Archimedes' principle, buoyancy and stability
- Hydraulic design principles and materials, mechanical advantage, common hydraulic components, sources of losses
- Viscosity, laminar and turbulent flow, Reynolds number, flow rate and continuity, Hagen-Poiseuille, Stokes' law, Bernoulli's principle and equation
- Math used on the test
- Standard arithmetic, including ratios, exponents and absolute value.
- Simple algebra: solving one equation for one variable.
- Simple geometry, such as areas and volumes of common shapes.
- Part II: device testing
- The layout and the Unmovable Battery are revealed at the start of the block; parts meant to touch the batteries can't be swapped after that
- 1 minute of Setup Time, then ready to run: surface-touching parts in the Device Box, battery contact part at or over the Finish Line, nobody touching the device
- Up to 3 minutes of Run Time to move the Movable Batteries into the Finish Zone (past the line, touching neither line nor Device Box) without disturbing the Unmovable one
- During the run, competitors touch only the Control Syringes: not the device, batteries or Test Surface
- Up to two adjustments if the device stops, jams or fails; each is penalised, can't move a battery, and the clock keeps running
- A leak stops testing at once with no further chances to score; a device that leaks before the run isn't tested
- The run ends at 3 minutes, when the team declares it finished, or at a leak; 4 minutes is recorded after a leak or unless all three Movable Batteries are in the Finish Zone
- A team appealing a Part II result leaves its device in the competition area.
- Part I: written test
Scoring
- Final Score = Exam Score + Battery Score + Time Score, at most 70 points; high score wins
- Exam Score = 40 × (team's Part I score ÷ highest Part I score)
- Battery Score: 3 per Movable Battery in the Finish Zone, +2 each in the Goal Box, +2 each upright, −7 if the Unmovable Battery is displaced, −4 per adjustment, never below 0
- Time Score = 9 × (lowest Run Time of all teams ÷ team's Run Time); 0 for a leak or without all three Movable Batteries in the Finish Zone
- No device, unsafe operation or an energy storage violation (3.a): zero Battery and Time Scores, but the team still takes the test
- Each construction violation left after Setup Time multiplies the Battery and Time Scores by 0.7
- Each competition violation multiplies the Battery and Time Scores by 0.9
- Not impounding the device with all spare parts and tools multiplies the Battery and Time Scores by 0.5
- Tiebreakers: best Time Score, then best Exam Score, then preselected test questions
Paraphrased by SciPrep from the 2027 Science Olympiad Division C Rules Manual, pages C67–C69. The official rules are in the Rules Manual from Science Olympiad; when they differ, the manual and its clarifications win.